Over time, electrical wiring naturally deteriorates. Fixed Electrical Testing, also known as Periodic Inspection and Testing or an Electrical Installation Condition Report (EICR), is carried out to assess the safety of your building’s electrical installation and confirm it remains in a safe condition.
UK legislation, including the Electricity at Work Regulations 1989, places a duty on employers and duty holders to ensure electrical systems are maintained safely. Periodic inspection is not simply paperwork, it is a practical process designed to identify faults, reduce risk, and help prevent fire or electric shock.
RB Services carries out periodic electrical testing and EICR inspections for businesses across the Midlands, helping organisations maintain safe electrical installations and clear inspection records.
Regulations 4(1) and 4(2) of the Electricity at Work Regulations require electrical installations to be designed, installed, constructed and maintained safely at all times.
Periodic inspection and testing is based on guidance from BS 7671 Wiring Regulations and is used to demonstrate that fixed wiring systems continue to meet safety standards. Regular inspections help highlight deterioration, damage, or non-compliance before issues become dangerous.
Our qualified engineers carry out both detailed visual inspections and calibrated electrical testing in line with current wiring regulations.
During the inspection we look for existing faults and potential risks that could lead to fire or injury. Where defects are found, we explain the findings clearly and can carry out remedial repairs if required. This allows issues to be addressed promptly and helps prevent future failures.
We work efficiently to minimise disruption and can offer out-of-hours testing where daytime access is limited.
Fixed Electrical Testing covers all permanent electrical systems within a building, including:
Distribution boards and circuit breakers
RCD protection
Earthing and bonding
Fixed cabling throughout the property
Switches, sockets and lighting circuits
Air conditioning units and other fixed plant
This applies to commercial, industrial and residential installations.
Each inspection produces an Electrical Installation Condition Report (EICR), documenting test results and identifying any defects. These may include exposed conductors, damaged containment, inadequate earthing, broken covers, or deteriorated cabling.
Electrical installation testing is completed in accordance with BS 7671 and typically includes:
Visual inspection
Continuity of protective conductors and bonding
Ring circuit continuity
Insulation resistance
Polarity
Earth fault loop impedance
Prospective fault current
RCD operation
Functional testing
All results are recorded within your EICR documentation.
Recommended inspection intervals vary depending on the type and use of the property.
General guidance suggests:
Every 3 to 5 years for most commercial and industrial premises
Every 10 years for domestic properties
However, usage, environment and equipment type may require more frequent testing. A site assessment helps determine the most appropriate inspection schedule.
RB Services provides professional fixed electrical testing carried out by qualified engineers with experience across a wide range of workplaces. Our inspections are structured, practical, and focused on identifying real safety risks rather than producing generic reports.
We provide:
Clear Electrical Installation Condition Reports (EICRs) with straightforward observations
Honest guidance on any remedial work required
Flexible appointment times to minimise disruption
Engineers experienced in both inspection and repair work
Consistent documentation suitable for audits, insurers and internal safety records
Our aim is to help you manage electrical safety responsibly, with clear outcomes and dependable service.
RB Services provides periodic electrical testing and Electrical Installation Condition Reports (EICR) for businesses and organisations across the Midlands. Our engineers carry out fixed electrical inspections across a wide range of commercial and industrial premises.
We regularly provide periodic inspection and EICR testing in areas including:
Birmingham
Burton upon Trent
Cannock
Coventry
Derby
Dudley
Leicester
Lichfield
Nottingham
Solihull
Tamworth
Walsall
Wolverhampton
If your location is not listed, please contact RB Services to discuss your electrical testing requirements.
If you require periodic electrical inspection or an Electrical Installation Condition Report, contact RB Services to arrange testing or request a quotation.
Our team will confirm availability, discuss your installation requirements, and schedule inspection at a time that suits your workplace.
You can also combine EICR testing with:
PAT Testing
Electrical Repairs
Fire Extinguisher Servicing
during a single visit where appropriate.
Remedial electrical works following inspections, plus ongoing maintenance to help keep systems safe, compliant, fully operational, and reduce the risk of future faults.
Ensure your fire safety equipment is always in optimal condition with our professional fire extinguisher servicing. Trust our experts to keep your extinguishers ready for any emergency situation.
Trust RB Services for comprehensive Portable Appliance Testing (PAT). Our expert technicians ensure safety and compliance, providing thorough assessments and detailed reports for your peace of mind.
An Electrical Installation Condition Report is a detailed inspection of a building’s fixed electrical installation. The inspection assesses the safety of wiring, circuits and electrical equipment to confirm that the installation remains safe for continued use.
UK regulations require electrical systems to be maintained safely. Periodic electrical inspection helps duty holders demonstrate that electrical installations are being maintained in a safe condition.
During a periodic electrical inspection, engineers carry out both visual inspection and electrical testing of the fixed wiring system. This includes testing circuits, earthing arrangements, protective devices and other parts of the electrical installation.
The duration of an EICR inspection depends on the size of the building, the number of circuits and the complexity of the installation. Larger commercial premises will naturally take longer than smaller installations.
You can contact RB Services directly or complete the enquiry form on our website to arrange fixed electrical testing or request a quotation.